When comparing our current climate data to last year, we noticed the average temperature inside the greenhouse on week 39 2022 was about 3° warmer than we are experiencing this time around.
This can be attributed to a few factors, one of them being that the average temperature outside was warmer. Another important factor to consider is that during fall 2022, the gutter vents were malfunctioning, reducing the airflow and increasing the temperature.
To help maintain a higher temperature, we adjusted the cooling temperature to 25°, which means the ambient temperature should get higher for longer period of time during the day. Ideally, this should help with growth, and water absorption.
Greenhouse Action:
Cooling Target: 25°
Heating Target: 19°
Bench Heat: Off
Sidewalls:
Down
Shade Curtains:
Opened 100%
Irrigation:
Floor watered at 14:00
Climate:
Weather : Overcast and rainy
Temperature Max Zone 4: 26.45° at 14:09
Temperature Min Zone 4: 18.23° at 20:15
Mean : 20.69°
Humidity Max Zone 4: 70.5% at 00:01
Humidity Min Zone 4: 39.5% at 15:45
Mean: 59.3%
Temperature Max Zone 5: 27.28° at 14:29
Temperature Min Zone 5: 18.48° at 18:51
Mean: 20.96°
Humidity Max Zone 5: 62.5% at 00:01
Humidity Min Zone 5: 29.2% at 15:45
Mean: 52.02%